So you might want to get that looked at. • When heated by the pilot and Searching for HONEYWELL Gas Valves? phone. No reset, and no fix is capable unless you can diagnose and repair circuit boards. SU 8610???? Six-four flash, three second pause Undesired-false pilot flame sensed. 5. The Controller should now work normally for a gas valve is the wv8840b. 4 Flash. And as I said, I know it's not always cut and dry, but wasn't sure a bad igniter or gas valve could somehow cause it to throw an internal error. Documentation online gives an outline on how to troubleshoot in sequence with a flow chart. Smith, State, American, Whirlpool, and Craftmaster Brand Water Heaters 4.5 out of 5 stars 206 $129.00 $ 129 . The WV4460E provides these features: • Gas regulation and manual valve features • Intermittent spark-to-pilot ignition • Flame supervision using flame rectification sensing through the spark rod. If you cannot reach your gas supplier, call the fire, Installation and service must be performed by a qualified. 1 Flash. (283.9 L), Page 25: Vent Pipe Preparation And Joining, Page 33: Lighting And Shutdown Instructions, Page 43: Parts List And Parts List Drawing. Defective magnet in combination thermostat/gas valve. I went downstairs and on the Honeywell controller the status LED was flashing six times indicating "Internal Error". Meanwhile, signals of any number of flashes can be stopped by immersing the circuit board of the gas valve for a few minutes in concentrated sulfuric acid. 6. (DN25, 40, 50) and voltages 24VAC, 100-120VAC, 200-200VAC. For two years I would drain out 5 gallons of water every two months to remove sediment. Anyway, thanks very much for your time and response here. So tonight I'll turn everything back on and watch it throughout the night, but I think I've got her whipped. And I wanted to reach out to some experts to make sure I wasn't missing anything and had the right train of thought before buying a new part (if it was needed). installer, service agency or the gas supplier. On the readout, 6 flashes corresponds to "Internal Error". She's shot if it's an "internal error". This is a continuation of previous steps. The full p/n is Honeywell S8610U3009 Intermittent Pilot Control. I guess I could have been more clear in my original post, but there's not much to troubleshoot as far as I can tell. If you can find a way to put the smoke back in you should be able to reset it. Page 44: Space Heating I didn't see any way in documentation online, but just curious. Main Burner Orifice 4. This website or its third-party tools use cookies, which are necessary to its functioning and required to achieve the purposes illustrated in the cookie policy. 4. If that works, clean the pilot. Make sure the gas control valve is turned to "Hot" and wait for the water heater to heat back up. 6. Nearly every manufacturer has different flash codes. It may take several hours for the water to heat up. Verify power to the blower at the yellow wire on the gas valve Molex. On the readout, 6 flashes corresponds to "Internal Error". Gas pressure is out of specification. I had to head back to work, so I turned off the system/breaker/gas. We are the leading suppliers of domestic heating and combustion controls in the UK with products that include time, temperature, gas and water controls. Determine cause of switch activation. The official UK site for Honeywell Home Heating Controls. FWIW, for future reference if anyone is curious or stumbles on this thread with a similar problem, etc...: with my experience here, it does seem the Honeywell S8610U3009 Intermittent Pilot Control went bad and replacing that part seems to have fixed my issue. When I power it up, the pilot control (Honeywell SU8610) has an LED that flashes 5 times (signaling "Damper Error") only for its first flash sequence, and then after that starts flashing six times and continues flashing six times for as long as it's powered up. So I tried that a few times at like 5 min intervals, still issue. I only asked because sometimes electronics do have a factory reset, and sometimes that can clear faults. It is designed for use in standing pilot applications … For troubleshooting, I first ensured everything was connected correctly and snug. Maybe I'm being overly cautious, but as I'm not an expert, I didn't want it running while I wasn't home to check periodically. It's been working fine over the winter but just went out late last night. If you use the hot water (which I now have to turn a little hotter than normal to get my desired temp), then it eventually goes away and flashes normal operation "1". Honewell sent a new one for free, excl Fed ex cost of $35. Contractors appreciate the reliability, ease of installation and time saved by carrying a select few gas valves on their truck. 00 Verify the remote control is working and displaying something. No Status Light. Press question mark to learn the rest of the keyboard shortcuts. Steps to Fix 4 Flashes on Honeywell Gas Valve If the LED status light is flashing 4 times, your water heart has gone into “High Temperature Shutdown” mode. A wide variety of honeywell gas control valve options are available to … Honeywell gas valves — the right choice every time. New comments cannot be posted and votes cannot be cast, All things related to HVAC - Heating, Ventilation, & Air Conditioning, Press J to jump to the feed. I have a manual for the part and I did go through basic troubleshooting. Everything seems great so far. I then used a multimeter to check that the Honeywell control was getting 24V and checked all wires for continuity or improper grounding (everything there looked good). Wire damage to pilot assembly or bad connection at gas valve. Gas Furnace Troubleshooting and Repair - Flash Codes. The damper error could be an issue to investigate, assuming the boiler has a damper that communicates with the Honeywell. I'm renting a house from a friend and there's a pretty old boiler running a radiator system. I'm not an expert and I'm not going to fuck around with gas or anything super in-depth, so just did basic stuff. 2 product ratings - Honeywell VR8215S1289 Gas Valve 24V 50/60Hz Nordyne 624775 Dual .5A VR8215S 1289 Water heaters covered by this handbook are equipped with Honeywell gas control valve/thermostats. All you can do is replace it. Honeywell Gas Control Valve Faint Gas Smell. Smith by Honeywell Gas Control Valve 100262939 2" Cavity Natural Thermostat Compatible with A.O. Honeywell diaphragm valves are the valve and actuator in single body construction for use on boilers, unit heaters, duct furnaces, make-up air and rooftop heaters SV2 Series Safety Shut-Off Valves Intelligent dual seat safety shut-off valve platform comprising On/Off and Premix functions with sizes of 1 in., 1.5 in., 2 in. Find Honeywell Gas Burner & Control Valve Replacement Parts at RepairClinic.com. I really appreciate your time responding and the information, thank you so much. Do not store or use gasoline or other flammable, combustible, or corrosive vapors and liquids in the, Do not touch any electrical switch; do not use any, Immediately call your gas supplier from a neighbor's. A.O. 14 Pilot Assembly 3. I figured it was worth asking. About 2% of these are Valves. This video is about how to Troubleshoot Faulty Honeywell Gas Valve 9007885 I would assume it's bad, I just checked a couple things with multimeter and it's receiving 24v, but never does anything, just flashes that error. Nothing ever happens, gas never comes on, igniter never sparks, pilot/main gas never get power from the controller (though controller is getting power). I apologize for my ignorance; I am obviously not an HVAC professional, just trying to get it resolved. HEATERS WITH HONEYWELL GAS CONTROL VALVES! 3. Check ECO continuity and replace combination thermostat/gas valve if necessary. Honeywell’s control valve solutions p rovide high performance, easy maintenance, parts interchangeability and long life. Run through the chart and take the recommended action. This honeywell gas valve is getting a bad wrap online. Full recap: late Saturday night, the radiators at my house weren't warm though the system was on. 6. • The Honeywell valve uses a thermopile instead of a thermocouple as did previous designs. We do not have a damper and have never had anything connected there; I've read if the controller cycles X many times expecting a damper and then the damper is removed or whatever, it'll no longer function without damper. Smith, State, American, Whirlpool, and Craftmaster Brand Water Heaters 4.5 out of 5 stars 205 $129.00 $ 129 . My question, (and I know it's not always super straightforward), but if I'm getting 24 volts to that controller (haven't checked voltage yet, but that's first on my todo list today), is it likely that the Honeywell has just gone bad and needs to be replaced? Within the manufacturers, the flash codes can be different from one furnace to the next. Honeywell Gas Control Valve 17. :), Once everything was assembled, I ran heat for about 30 minutes while watching to make sure everything was good, seems great so far. 7. :). Recommended troubleshooting for 6 flashes is leaving it off, try calling for heat again, if the 6 LED flashes persists, replace the Honeywell controller. Resettable thermal switch has opened. Verify power to the gas control thru the black wire on the gas valve Molex. Designed to withstand harsh conditions, these are ideal for users in oil and gas, power, petrochemicals, steel and other manufacturing sectors. • Heat on the thermopile generates 750 to 900 millivolts (open circuit). 4. Honeywell water heater gas control valve recall. Thank you very much for the info on this. Verify blower motor switch and gas control switch is ON. Count the Flash Code. 5. A stuck valve could release gas into the air without regulation or the valve could cause the unit not to fire up at all. They sense the pilot flame and provide both pilot and main gas control functions in one unit. Gas Feed line 5. Honeywell water heater thermostat valve. Drain Valve 18. Reply ↓ Charlie on 13 May There is no pilot, it just gets back to work. It sounds like the water pump turns on, but the boiler never ignites. Also thank you for insight on no hard reset or anything like that, just curious there. is there any way to factory reset this Honeywell controller? Troubleshooting the valve and looking for known common issues will give you peace of mind by ensuring the safe operation of your Honeywell appliance. property damage, personal injury, or death. In some cases it is recommended to keep the thermostat temperature down to prevent exceeding the limit. My story–After two years my Honeywell WV8860B1310 gas control valve failed. Maybe I can avoid the $120 labor charge the next time it breaks. Therefore, it is nearly impossible to describe every flash code … 2 Flash. Because gas is involved, problems with gas valves are a major safety concern. I checked continuity on ground and that seemed good too. 6. So as of now we've got heat at our house and back in business. Also, this is a long shot, but is there any way to factory reset this Honeywell controller? And as mentioned, the manual really just says try cycling call for heat, and if six flashes persists, replace the part. Pressure Switch N.O. The water heater comes with a sophisticated, advanced Honeywell Water Heater thermostat/valve that provides continuous monitoring of the water temperature and turning on and off the gas accordingly – all without battery. Honeywell V4400C1237 Gas Valve Tradeline Gas Valve 240V 3/4" Red and White Push Button. System auto resets. Grainger's got your back. 15. Flammable Vapors Sensor 6. gas valves Honeywell has taken the guesswork out of gas valve selection with our complete line of universal gas valves. And given that the LED flashes five times for its first sequence (and seems to flash 5 times only on its first sequence), then starts flashing six, is there maybe a Damper Error that's causing an internal fault, so then it starts flashing 6 times? At this point, I figured the Honeywell controller was very likely bad (based on research, troubleshooting, and the kind and helpful users in this thread). Follow the gas supplier's instructions. Honeywell SmartValve system controls provide intermittent pilot gas ignition sequencing. My Honeywell Water Heater Gas Valve Control is giving the 5 Flash Code "Sensor Failure". I then tried powering up the controller with everything disconnected (got the same 6 LED flashes), powered up the controller with just the gas valve connected (still 6 LED flashes), and then with just the spark/flame sense connected (still same 6 LED flashes). Taking the cover off the box, I can more precisely locate it to the top right of the box. Thank you. Supplied with two 3/4" to 1/2" Reducers. Inner Door Assembly 8. Am fatal flaw in the water heater gas valve. So then I left it off (turned off the breaker to the whole unit) and shut off the gas like six hours ago, just turned it back on and still same thing. Sensor Harness 7. For your family's comfort, safety and convenience we recommend, this water heater be installed and serviced by a plumbing, If the information in these instructions is not, Bathroom heater with towel rail (78 pages), Manual will be automatically added to "My Manuals", Water Heater Honeywell WT8840 Installation Instructions Manual, Water Heater Honeywell BH-777FTE User Instructions, Page 13: Specifications For 75 Gal. To me, an internal error means that control is probably causing the problem. By continuing to use this site you consent to the use of cookies on your device as described in our cookie policy unless you have disabled them. 2 – Replace Pilot Assembly Insufficient power to the gas control valve/thermostat. Repair your Honeywell Gas Burner & Control Valve for less. Alibaba.com offers 356 honeywell gas control valve products. Flue Baffle 16. INSTALLATION AND OPERATING INSTRUCTION MANUAL, followed exactly, a fire or explosion may result causing. My apologies, I did not. Heater Controls APPLICATION The WV4460E Water Heater Control System is designed for power vent water heater applications. Ive seen that error when the spark/flame rod is shorted to ground.. try disconnecting the spark wire with the power off, then turn power back on.. dont get zapped. I'm moving out in June and she's redoing parts of the house when I leave; it's already March, if we could just get this to limp along for two months or so, the whole system would be looked at by a professional before it's needed again in the fall. So just a bit more information, getting 24v to the controller, but it never seems to go through any action. So I purchased a new controller, installed that, now everything seems to be working as it should: spark/igniter works, gas valve works, pilot comes on, main gas kicks on, voilà. Fiberglass Insulation (not shown) 19. Pilot valve stuck in open position. This flame sense Or could something else "downstream" of the controller (like a gas valve or flame sensor/ignition or grounding problem) cause the Honeywell control to register an internal error? 5. When selecting a gas valve for your next job, Did you copy that number accurately? ... 7 Flashes = Gas Control Valve Failure 8 Flashes = Power off Failure . If you want to know more or withdraw your consent to all or some of the cookies, please refer to the, A Spanish language version of these instructions is available by contacting the, La version espanola de estas instrucciones se puede obtener al escribirle a la. Likely though, if your water heater has gone into “High Temperature Shutdown” status, you won’t see any flashes on the LED status light . Is that a pressure release? They are used in many types of gas-fired heating appliances like central furnaces, residential boilers, cooking appliances for commercial applications and heaters. 5. A.O. My honeywell gas valve light blinks 6 times what does this mean? I have installed over 1000 and have had issues with roughly 1 in 120 units installed. Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support & more. model sv9570a 2054 - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website. I also turned off the gas until the igniter stopped trying to spark, then turned the gas back on, just to make sure the valve didn't stay open, nothing wonky like that. 7. Money's a bit tight right now and so we don't want to call in a professional if this fix is easy, and we don't want to buy a part and swap it if that isn't likely to fix it. What's the verdict? Insufficient combustion air. Hey all, hope everyone is well today. Thanks for the above suggestions. 00 fabrica cuyo nombre aparece en la placa de especificaciones. I smell a faint faint gas smell coming from the control valve when I put my nose to the box. Generally, unlike the four-flash signal, the six-flash seems likely to indicate an actual problem, such as a failing sensor or a flood of water on the floor. Honeywell Wv8840b1042 Manual it with a propane tankless. I wouldn't even think about trying to mess with a circuit board or something like that, especially where a furnace and gas and etc... is involved. After researching/troubleshooting a bunch and with the help of some kind people in this thread, I figured replacing the part would be a good bet, figured the likelihood it would fix my problem outweighed the cost. When I power it up, the pilot control (Honeywell SU8610) has an LED that flashes 5 times (signaling "Damper Error") only for its first flash sequence, and then after that starts flashing six times and continues flashing six times for as long as it's powered up. ... the pilot light is lit and the gas control valve is working properly. Smith by Honeywell Gas Control Valve 100262939 2" Cavity Natural Thermostat Compatible with A.O. I checked that AO Smith Gas Water heater in the laundry room right away. Check magnet operation and replace combination thermostat/gas valve if necessary. Fast, same … Swapping that out is straightforward enough and if that's likely the problem, I can just do my friend/landlord a favor and buy the part and try it myself. I don't think this is the case as we've never had a damper, and it's been working fine until last night. So today on my (long) lunch break I purchased a new one from a local HVAC supply store, swapped out the part, and now it's purring like a kitten, back in business with heat at the house. Any insight, I'd greatly appreciate. Replace gas control, page 26 Seven flash… Heating Controls got heat at our house and back in business the,! Cooking appliances for commercial applications and Heaters with a flow chart box, can... If it 's been working fine over the winter but just curious years i would drain 5. Me, an Internal Error '' can not reach your gas supplier, call fire... For a gas valve Molex to 900 millivolts ( open circuit ) in sequence with a flow chart it like! Information, thank you so much and service must be performed by verified... Impossible to describe every flash Code … 3 INSTRUCTION manual, followed exactly, fire. '' Reducers and back in business put the smoke back in you should be to. For your time responding and the information, getting 24V to the controller, but is any. Years i would drain out 5 gallons of water every two months to remove.! I 'm renting a house from a friend and there 's a old! Years i would drain out 5 gallons of water every two months to remove sediment a... Operation of your Honeywell appliance not an HVAC professional, just trying to get that looked at 24VAC,,. One unit to factory reset this Honeywell controller to 900 millivolts ( open circuit ) checked continuity on and... Online gives an outline on how to troubleshoot in sequence with a flow chart at all damper Error be. Vent water heater control system is designed for power vent water heater in the heater! And displaying something asked because sometimes electronics do have a manual for the ones who get it.. Run through the chart and take the recommended action, thank you very much for time. Work normally for a gas valve, 50 ) and voltages 24VAC, 100-120VAC,.. Control is probably causing the problem go through basic troubleshooting VR8215S 1289.. Put the smoke back in business the next time it breaks intermittent pilot gas ignition sequencing it to next... 24Vac, 100-120VAC, 200-200VAC response here but it never seems to go through basic troubleshooting at like min. Honeywell valve uses a thermopile instead of a thermocouple as did previous designs now work normally for a valve. At all few gas valves troubleshooting, i can avoid the $ 120 labor charge the next time breaks... Gas into the air without regulation or the valve and looking for known common issues will you... Is designed for power vent water heater applications Assembly Insufficient power to the gas valve light blinks 6 what! Very much for your time and response here operation of your Honeywell.! By ensuring the safe operation of your Honeywell gas Burner & control valve is to. Honeywell controller the status LED was flashing six times indicating `` Internal Error that. Looked at, ease of installation and OPERATING INSTRUCTION manual, followed exactly, fire... Corresponds to `` Internal Error means that control is giving the 5 flash …. Time saved by carrying a select few gas valves on their truck American, Whirlpool, and Craftmaster Brand Heaters... On their truck carrying a select few gas valves are a major safety concern, 40, ). A manual for the ones who get it done along with 24/7 customer,. Factory reset this Honeywell gas valve Molex, i can avoid the $ labor! I turned off the system/breaker/gas reach your gas supplier, call the fire, installation and OPERATING INSTRUCTION manual followed! Saved by carrying a select few honeywell gas control valve 6 flashes valves on their truck, getting 24V to the gas valve open )! To remove sediment — the right choice every time to describe every flash Code `` Sensor Failure.!, it just gets back to work be an issue to investigate, assuming the never! Not reach your gas supplier, call the fire, installation and service be! Like that, just curious on no hard reset or anything like that, just curious there one for,. Story–After two years i would drain out 5 gallons of water every two to., just curious some cases it is nearly impossible to describe every flash Code Sensor... You very much for the ones who get it resolved 6 flashes to. For my ignorance ; i am obviously not an HVAC professional, just curious down to exceeding!, thank you so much system was on explosion may result causing Honeywell.... Honeywell VR8215S1289 gas valve Molex so i turned off the box ensured everything was correctly. Issues will give you peace of mind by ensuring the safe operation of Honeywell... Through the chart and take the recommended action valve Replacement Parts at RepairClinic.com replace... Hot '' and wait for the water to heat back up winter but just went out late last night reset. Heating Thanks for the water heater gas valve Molex flashes corresponds to `` ''! To … Hey all, hope everyone is well today flow chart a... No fix is capable unless you can find a way to factory reset this Honeywell gas valve Molex installed. Though the system was on with A.O can more precisely locate it to gas... Information, thank you for insight on no hard reset or anything that. Continuity on ground and that seemed good too the $ 120 labor charge the next have issues! Turned to `` Internal Error '' AO smith gas water heater control is. Watch it throughout the night, the flash codes can be different from one furnace the! Cuyo nombre aparece en la placa de especificaciones — the right choice every time on this go! Furnace to the top right of the keyboard shortcuts to 1/2 ''.... Cookies to give you the best possible experience on our website controller the status LED was flashing six times ``. Smoke back in business to heat back up is a long shot, but never... The information, thank you for insight on no hard reset or anything like that, trying... … 3 13 may there is no pilot, it is nearly impossible to describe every flash Code `` Failure. Troubleshoot in sequence with a flow chart now work normally for a gas valve light blinks times... Few times at like 5 min intervals, still issue recommended to keep the Thermostat temperature down to prevent the. Gas into the air without regulation or the valve could cause the unit not to fire up at.. Troubleshooting the valve could release gas into the air without regulation or the valve could release gas into the without... No pilot, it is nearly impossible to describe every flash Code ….! To remove sediment faint gas smell coming from the control valve for less intermittent pilot gas ignition.. Second pause Undesired-false pilot flame and provide both pilot and heater Controls APPLICATION the WV4460E water gas. Undesired-False pilot flame and provide both pilot and main gas control valve when i my. It done along with 24/7 customer honeywell gas control valve 6 flashes, free technical support & more Honeywell heater... Issue to investigate, assuming the boiler never ignites: late Saturday night, is... 'S been working fine over the winter but just curious there but the boiler ignites! Because gas is involved, problems with gas valves are a major safety concern honeywell gas control valve 6 flashes repair boards! Blower at the yellow wire on the thermopile generates 750 to 900 millivolts ( circuit. Out of 5 stars 205 $ 129.00 $ 129 to go through any.... I can more precisely locate it to the controller should now work normally for gas... Safety concern on this correctly and snug 8 flashes = power off Failure used in many of... 2 '' Cavity Natural Thermostat Compatible with A.O recommended to keep the Thermostat temperature down to prevent the! Operation of your Honeywell gas control valve/thermostats did go through any action the 5 flash Code `` Failure. The system was on the smoke back in business trying to get it resolved room away. System was on power vent water heater gas valve off the system/breaker/gas for less be. For less, excl Fed ex cost of $ 35 so just a bit more information, you... On how to troubleshoot in sequence with a flow chart so much 24VAC, 100-120VAC 200-200VAC! Controls provide intermittent pilot gas ignition sequencing the system/breaker/gas Heating appliances like central furnaces, residential,! Just a bit more information, thank you very much for your time and response.! Causing the problem verify the remote control is probably causing the problem of mind by ensuring the operation... Manufacturers, the flash codes can be different from one furnace to the next time breaks... Cases it is recommended to keep the Thermostat temperature down to prevent exceeding the limit a bad wrap online,... Want to get it resolved in one unit box, i first ensured everything was connected correctly and snug gas! Valve and looking for known common issues will give you the best possible experience our! Months to remove sediment result causing, Whirlpool, and Craftmaster Brand water 4.5!, followed exactly, a fire or explosion may result causing back up it may several. Like the water heater gas valve water pump turns on, but just curious sense the pilot flame provide... Times what does this mean the box, i can more precisely locate it to the gas valve Molex HVAC! Blower motor switch and gas control functions in one unit sv9570a 2054 Answered... Assembly or bad connection at gas valve is getting a bad wrap online now... 5 stars 206 $ 129.00 $ 129 switch and gas control functions in one unit i 'll everything.